Using this technique systematically, along with the techniques described previously, will usually identify the nonlinearities in the model that are leading to issues. Hello, Set initial conditions in the physics to the appropriate dependent model variable names rather than the default 0. Get notified about new Stationary Engineer jobs in Brea, California, United States. If it does so, use a finer increment in that range. Communication over the phone, in person, and through email was very easy. It is thus always advised to start this procedure with a simplified 2D, or 2D-axisymmetric model. It can be useful while solving sequences of linear systems arising from, for example, nonlinear problems. Here, we will examine techniques for accelerating the convergence of these two methods. A Global Parameter has to be introduced (in the above screenshot, P) and is ramped from a value nearly zero up to one. Ramping the nonlinearities over time is not as strongly motivated, but step changes in nonlinearities should be smoothed out throughout the simulation. How do/should administrators estimate the cost of producing an online introductory mathematics class? Note the star symbol on the Solution feature. Ramping the nonlinearities over time is not as strongly motivated, but step changes in nonlinearities should be smoothed out throughout the simulation. See also: Knowledge Base 1254: Controlling the Time Dependent solver timesteps. This solver is automatically used when a Stationary or Frequency Domain study is added to the model. Segregated approach and Direct vs. If you have both as steps in the same study, then solve that study. Why? The issue here has do with the iterative algorithm used to solve nonlinear stationary models. k(T) = 10[W/m/K]+10[W/m/K]*(T>400[K]) By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. See also: Knowledge Base 1254: Controlling the Time Dependent solver timesteps. Use either a very fine mesh throughout the simulation domain or use adaptive mesh refinement. Staging Ground Beta 1 Recap, and Reviewers needed for Beta 2, Simulation of effect of heated resistance on temperature distribution in laminar flow, COMSOL: Diffusion in Transport of Diluted Species Produces Unphysical Results. Please dont hesitate to post comments below or send emails to us if you experience any other problems. The Automatic predictor setting will use the constant predictor when a segregated solution approach is being used, and use the linear predictor when the fully coupled approach is used. The settings controlling the predictor type. [COMSOL_Users] output of stationary solver as input to time-dependent In the extreme case, suppose one wants to model an instantaneous change in properties, such as: Assuming a well-posed problem, the solver may converge slowly (or not at all) if the initial values are poor, if the nonlinear solver is not able to approach the solution via repeated iterations, or if the mesh is not fine enough to resolve the spatial variations in the solution. Posted 26 set 2019, 11:57 GMT-4 Feature: Stationary Solver 1 (sol1/s1) Attempt to evaluate nonintegral power of negative number. Stationary Solver - COMSOL Multiphysics That is, within each outer Newton-type iteration, the segregated approach solves for each segregated group sequentially. GCRO-DR is a method for Krylov subspace recycling. The segregated approach, on the other hand, solves sets of unknowns separately. This parameter is used within the physics interfaces to multiply one, some, or all of the applied loads. The prices are good, and when I needed something delivered, same day, they were able to do it, and it looked beautiful!! Here, we begin an overview of the algorithms used for solving nonlinear static finite element problems. This approach is known as a Continuation Method with a Constant predictor. The unknowns are segregated into groups, usually according the physics that they represent, and these groups are solved one after another. If this was solved using the Solid Mechanics physics interface the thin walls of the container would need to be explicitly modeled, but the wall thickness is much smaller than the overall can dimensions. This involves a systematic reduction in the model complexity. Nonlinearity ramping is an especially useful technique if any of the nonlinear terms in the model are very abrupt. If you still need help with COMSOL and have an on-subscription license, please visit our Support Center for help. Linear solvers. See Knowledge Base 1240: Manually Setting the Scaling of Variables. listed if standards is not an option). See also: Knowledge Base 1254: Controlling the Time Dependent solver timesteps. This is for COMSOL 5.2, but should be similar for 4.2: Create the stationary study. What did people search for similar to stationary stores in Brea, CA? "After the incident", I started to be more careful not to trip over things. Any trademarks referenced in this document are the property of their respective owners. The finite element mesh must be fine enough to resolve the spatial variations in the solution fields. Changes to these low-level settings from the defaults will usually be quite model- and case-specific. If instead the model is linear, see: Knowledgebase 1260: What to do when a linear stationary model is not solving. At a value of P=0 the above expression is linear, and at a value of P=1 the expression is equal to the original nonlinear expression. Consult your product manuals for complete trademark details. I personally liked emailing them the file, ", "This flower shop is the best! Review the model setup to resolve these. The segregated approach, on the other hand, solves sets of unknowns separately. The coupling terms between the different groups are thus neglected. How to solve "Undefined material property 'sigma - ResearchGate (Frequency Domain should be the last step) That is, the material property changes instantaneously from 10W/m/K to 20W/m/K at 400K. They deal with COMSOL package and train users. Contact COMSOL at Bangalore on their telephone: +9180 25323003. Get email updates for new Stationary Engineer jobs in Brea, California, United States. Once a simplified solvable version of the model has been found, gradually increase the model complexity again, re-introducing nonlinearities and multiphysics couplings. By providing your email address, you consent to receive emails from COMSOL AB and its affiliates about the COMSOL Blog, and agree that COMSOL may process your information according to its Privacy Policy. This approach is used by default for most 1D, 2D, and 2D-axisymmetric models. There will always already be either a Segregated or Fully Coupled feature beneath this. Alle Rechte vorbehalten. It is thus always advised to start this procedure with a simplified 2D, or 2D-axisymmetric model. The software then computes an initial solution and from there it iteratively re-computes the solution, taking into account how these intermediate solutions affect the nonlinearities. Despite this, the segregated approach can often converge very robustly, unless there are very strong couplings between the physics in the model. This information is presented in the context of a very simple 1D finite element problem, and builds upon our previous entry on Solving Linear Static Finite Element Models. This will use the initial conditions you specified in your physics setting (usually 0 is used in the physics settings). That is: It is also possible to compute the derivative of the solution with respect to the continuation parameter and use that derivative (evaluated at the iteration) to compute a new initial value: where is the stepsize of the continuation parameter. - the incident has nothing to do with me; can I use this this way? The Fully Coupled solution approach, with the Plot While Solving enabled. If you are unsure if your problem is linear and stationary, look at the Log. This is relatively expensive to do, but will lead to the most robust convergence. If it does so, use a finer increment in that range. COMSOL does not assume any legal liability for the accuracy of the data disclosed. If your matrix is singular than no solver in the world can solve Ax=B. There are two approaches that can be used when iteratively solving the nonlinear system of equations: a Fully Coupled or a Segregated approach. Does anyone know how to solve error in stationary solver in COMSOL Using this technique systematically, along with the techniques described previously, will usually identify the nonlinearities in the model that are leading to issues. Repeat this for every nonlinearity of the model. Load ramping and nonlinearity ramping can be used in combination, but start with only one or a few of the loads or nonlinearities being ramped. Not assigning proper boundary conditions: Especially if you have ports. To start a new discussion with a link back to this one, click here. Consult your product manuals for complete trademark details. As we saw previously in the blog entry on Solving Nonlinear Static Finite Element Problems, not all nonlinear problems will be solvable via the damped Newton-Raphson method. With the exception of some thermal problems however, it is often difficult to estimate the solution, so alternative approaches are needed. It's brand new in the hmart plaza and I wish it was open back when I would hangout in the plaza after school (although they would have taken all my allowance money! She opened prepackaged 6-packs of Seegars to make ", All "stationary stores" results in Brea, CA, Search stationary stores in popular locations. You can fix this by pressing 'F12' on your keyboard, Selecting 'Document Mode' and choosing 'standards' (or the latest version Sometimes, reducing the model complexity can be quite challenging and it can be better to start from as simple a case as possible and gradually increase the complexity. To switch between these solver types, go to the Stationary Solver node within the Study sequence. Using a predictor of type Constant will take the solution from the iteration and use it as the initial value for the iteration. It may also reveal that the model itself is ill-posed in some way. However, it is usually not possible to know this ahead of time. As a second example, when solving for Electric Currents, do not model perfect electrical insulators as materials with zero conductivity, instead, omit the domain from the model and use the Electric Insulation boundary condition. This case is generally difficult, or impossible, to solve since this material property is non-smooth. P&S: COMSOL Design Tool for Photonic Devices. COMSOL makes every reasonable effort to verify the information you view on this page. Today's top 351 Stationary Engineer jobs in Brea, California, United States. My comment is perhaps a bit nave but it seems to me that you could simply deactivate the \frac{\partial \cdot}{\partial t} term of the background field equation but keep its connexion to the solid to get what you want. k(T,P) = 10[W/m/K]*((1-P)+P*exp(-(T-293[K])/100[K])) Then use this file to provide the initial conditions in time dependent model. This parameter is used within the physics interfaces to multiply one, some, or all of the applied loads. When the difference in the computed solutions between successive iterations is sufficiently small, or when the residual is sufficiently small, the problem is considered converged to within the specified tolerance. The Continuation method is enabled by default when using the Auxiliary sweep study extension, as shown below. At low flow speeds the flow solution will be time invariant, but at higher flow rates there will be vortex shedding, a time-varying change in the flow field behind the cylinder. However, it is usually not possible to know this ahead of time. What to do when a linear stationary model is not solving - COMSOL listed if standards is not an option). Why doesn't iterative solver converge in COMSOL? - ResearchGate To switch between these solver types, go to the Stationary Solver node within the Study sequence. Sign in to create your job alert for Stationary Engineer jobs in Brea, California, United States. In such cases, see if one material (or the other) can be omitted from the analysis completely. Load ramping and nonlinearity ramping can be used in combination, but start with only one or a few of the loads or nonlinearities being ramped. It is sometimes necessary to manually scale the dependent variables. Assuming a well-posed problem, the solver may converge slowly (or not at all) if the initial values are poor, if the nonlinear solver is not able to approach the solution via repeated iterations, or if the mesh is not fine enough to resolve the spatial variations in the solution. In this blog post we introduce the two classes of algorithms that are used in COMSOL to solve systems of linear equations that arise when solving any finite element problem. This is relatively expensive to do, but will lead to the most robust convergence. I am solving a linear stationary finite element model but the software is not solving. You can fix this by pressing 'F12' on your keyboard, Selecting 'Document Mode' and choosing 'standards' (or the latest version When the difference in the computed solutions between successive iterations is sufficiently small, or when the residual is sufficiently small, the problem is considered converged to within the specified tolerance. - Feature: Stationary Solver 1 (sol1/s1) Adaptation gives the - COMSOL Numerically ill-conditioned means that the system matrix is nearly singular and that it will be difficult to solve on a finite-precision computer. This case is generally difficult, or impossible, to solve since this material property is non-smooth. Nonlinearities arise as a consequence of the governing equation, as a material nonlinear expression, or as a coupling term between physics. The Continuation method is enabled by default when using the Auxiliary sweep study extension, as shown below. It is sometimes necessary to manually scale the dependent variables. Could you expand a little bit more why the coupling is impossible? An example model that combines the techniques of nonlinearity ramping and adaptive mesh refinement with multiple study steps is: Solving such models in a stationary sense should simply require solving a single (large) system of linear equations and should always be solvable, but there are cases when the software will fail to find a solution. I have searched all over comsol forum to fix this stationary solver configuration and still doesn't work because I don't know the logic behind the solver system. Wish you all the best. If you try to enter a variable that is undefined, the automatic syntax highlighting will identify this as you enter it, and it is best practice to resolve this immediately. k(T) = 10[W/m/K]*exp(-(T-293[K])/100[K]) COMSOL makes every reasonable effort to verify the information you view on this page. Solving for laminar flow using Comsol - YouTube Second, the continuation method will automatically take smaller load increments if a solution cannot be found. Knowledgebase 1260: What to do when a linear stationary model is not solving, Knowledge Base 1240: Manually Setting the Scaling of Variables, What to do when a linear stationary model is not solving, Knowledge Base 1254: Controlling the Time Dependent solver timesteps, Galleria dei Modelli e delle App di Simulazione, 2023 da COMSOL. Such problems must solved in the time domain. Instead, use a nonlinear material property expression that ramps from a very smooth function to a very nearly discontinuous one. In the extreme case, suppose one wants to model an instantaneous change in properties, such as: Most multiphysics problems are nonlinear. If you define this nonlinearity ramping such that the first case (P=0) is a purely linear problem, then you are guaranteed to get a solution for this first step in the ramping. Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? You can unsubscribe from these emails at any time. At low flow speeds the flow solution will be time invariant, but at higher flow rates there will be vortex shedding, a time-varying change in the flow field behind the cylinder. Each physics is thus solved as a standalone problem, using the solution from any previously computed steps as initial values and linearization points. COMSOL Blog Series on COMSOL Multiphysics Solvers These are some cards & stationery with a large number of reviews in Brea, CA. For example, if ramping P over values of: 0.2,0.4,0.6,0.8,1.0 the nonlinear solver may fail to converge for a value of 0.8. As P is ramped up, the continuation method uses the previous solutions to compute initial conditions for the more nonlinear cases. Then I stored the resulting solution, and used it to to solve the stationary solver again by using the solver manager. COMSOL Error for Initial Values(RF Module) Sometimes, reducing the model complexity can be quite challenging and it can be better to start from as simple a case as possible and gradually increase the complexity. Nonlinearity ramping is an especially useful technique if any of the nonlinear terms in the model are very abrupt. The unknowns are segregated into groups, usually according the physics that they represent, and these groups are solved one after another. Feature: Stationary Solver 1 (sol1/s1)" . The Continuation method is enabled by default when using the Auxiliary sweep study extension, as shown below. Improving Convergence of Nonlinear Stationary Models, Knowledgebase 1030: Error: "Out of memory", Knowledgebase 1030: Performing a Mesh Refinement Study, Understanding the Fully Coupled vs. A classic example of this is fluid flow around a cylinder with high, but constant, flow rates. In this posting, we introduce the idea of ramping the nonlinearities in the problem to improve convergence. For more details, see: Performing a Mesh Refinement Study, Mesh refinement may often need to be combined with load or nonlinearity ramping and may require a set of studies, first starting with a relatively coarse mesh for nonlinearity ramping, refining the mesh, and the ramping further on the refined mesh.